NurseJet
Back to Discover
Systematic ReviewResearchWorkflow

Systematic review of 10,115 emergency chest pain patients finds point-of-care high-sensitivity troponin reliably rules out acute myocardial infarction on arrival

European journal of emergency medicine : official journal of the European Society for Emergency Medicine (PubMed)Oct 27, 2026

AI-summarized from the linked source. Educational brief, not medical advice.

Brief summary

A systematic review of 11 studies covering 10,115 emergency department patients with chest pain found that commercial point-of-care high-sensitivity cardiac troponin assays achieve 96.3% to 100% sensitivity and 98.1% to 100% negative predictive value for ruling out acute myocardial infarction upon arrival.

What NurseJet pulled from the source

High-sensitivity cardiac troponin (hs-cTn) assays have transformed emergency chest pain triage, but standard central laboratory processing often incurs turnaround delays exceeding an hour. This systematic review evaluated 11 studies (including both derivation and validation cohorts) comprising 10,115 adult ED patients presenting with chest pain suggestive of acute coronary syndrome to determine the diagnostic accuracy of four commercial point-of-care hs-cTn devices with turnaround times under 20 minutes. Applied as a single-test rule-out upon ED arrival, high sensitivity and negative predictive value (NPV) were documented: Atellica VTLi demonstrated 98.8% to 100% sensitivity for troponin <4 ng/L (NPV 99.8%–100%) and 100% sensitivity for <7 ng/L (NPV 100%); Pathfast showed 96.3% to 100% sensitivity for <3 ng/L (NPV 98.1%–100%); i-STAT achieved 99.8% sensitivity for <5 ng/L (NPV 100%); and TriageTrue achieved 100% sensitivity for <3 ng/L (NPV 100%). Serial testing using the 99th percentile across 0- to 3-hour protocols yielded variable sensitivities (VTLi 64.8%–100%, Pathfast 83%–87%, and TriageTrue 79.8%), demonstrating that POC assays are most reliable when utilized for rapid arrival rule-out at low thresholds.

Why this matters for nurses

Emergency nurses triage hundreds of potential acute coronary syndrome presentations where rapid risk stratification prevents bed overcrowding and expedites definitive interventions. Understanding that verified bedside hs-cTn devices deliver lab-comparable rule-out accuracy in under 20 minutes allows triage nurses and rapid-assessment teams to accelerate clinical decision-making, shorten emergency stays, and safely reassure low-risk individuals.

Bedside takeaway

A systematic review of 10,115 emergency patients showed point-of-care high-sensitivity troponin assays rule out acute myocardial infarction upon arrival with 96.3% to 100% sensitivity.

Key takeaways

  • Systematic review analyzed 11 derivation and validation studies encompassing 10,115 emergency chest pain patients.
  • Point-of-care hs-cTn devices provided rapid turnaround times (<20 minutes) suitable for bedside emergency testing.
  • Single-test arrival rule-out achieved 96.3% to 100% sensitivity and 98.1% to 100% negative predictive value across four commercial devices.
  • Serial protocols at the 99th percentile exhibited broader sensitivity variability (64.8% to 100%), favoring arrival threshold pathways.
  • Integration into clinical decision protocols can expedite low-risk rule-out while central laboratory confirmation remains prudent for ambiguous presentations.

Practice implications

  • When evaluating acute chest pain using point-of-care hs-cTn platforms, recognize that extremely low arrival concentrations offer high negative predictive value for acute myocardial infarction, but adhere strictly to facility serial draw algorithms and ECG evaluations for indeterminate or evolving symptoms.

Limitations & cautions

  • Review included both derivation and prospective validation studies evaluated via QUADAS-3; diagnostic accuracy varied considerably when serial testing was evaluated at the 99th percentile rather than arrival rule-out thresholds; devices cannot replace continuous electrocardiographic monitoring or clinical risk scoring.
  • AI-summarized from the linked source. Review the original article before applying to practice.

Citations

Exact source links

Public citations are filtered to exact credible source pages. Homepage-only or invalid links stay in admin review and are not shown here.

European journal of emergency medicine : official journal of the European Society for Emergency Medicine (PubMed)

European journal of emergency medicine : official journal of the European Society for Emergency Medicine (PubMed). Diagnostic accuracy of high-sensitivity point-of-care troponin assays in emergency department for patients presenting with chest pain: a systematic review.

Open original source

https://pubmed.ncbi.nlm.nih.gov/42894477/

Professional education only

This summary does not replace clinical judgment, facility policy, provider orders, or official guidelines. Verify practice changes against the original source and local protocol.

Related briefs

More updates for this clinical area

Back to Discover

Heart & lung : the journal of critical care (PubMed)

A randomized controlled trial of 66 adult cardiac surgery patients undergoing median sternotomy found that adding dexmedetomidine to bilateral transversus thoracic muscle plane blocks significantly prolonged time to first rescue analgesia and reduced 24-hour postoperative fentanyl consumption compared to bupivacaine alone.

ICUTelemetryAI summaryReview source

The American journal of emergency medicine (PubMed)

An updated systematic review and meta-analysis of five randomized controlled trials comprising 404 chest trauma patients demonstrated that applying suction following tube thoracostomy significantly shortened chest tube duration by 2.95 days and hospital stay by 3.98 days compared with water seal.

Med-SurgEmergencyAI summaryReview source

JAMA (PubMed)

A systematic review and meta-analysis of 85 randomized controlled trials encompassing 70,543 participants found that SGLT2 inhibitor therapy was associated with small, statistically significant increases in hemoglobin (+0.60 g/dL), hematocrit (+2.36%), and erythropoietin (+2.11 mIU/mL).

Med-SurgTelemetryAI summaryReview source